APPLICATION

REFRIGERATION SYSTEMS

 

  1. Home
  2.  » 
  3. Applications
  4.  » Refrigeration

Overview refrigeration

Refrigeration overview

Refrigeration
Industrial refrigeration Comfort cold Branch
Free cooling, cooling towers Compression chillers Compression chillers Types of cooling
> 20 °C -40 °C to +10 °C 6 °C to 20 °C Temperature range
Open and closed, also chemical-contaminated water cycles Coolant circuits (all known water-glycol mixtures, water-alcohol mixtures, brine) Recooling circuits of condenser cooling and oil cooling (water-glycol mixtures) Coolant circuits in air conditioning systems (water) recooling circuits of condenser cooling (water-glycol mixtures) Circulation types and refrigerants

Free cooling

Common problem with open recooling circuits:

 

  • severe corrosion due to strong oxygen enrichment in the cooling water
  • severe corrosion due to chemical additives in the cooling water 

Compression refrigerators for industrial refrigeration

Common problem with compression refrigerators:

 

  • increasing incrustation of steel pipes
  • thus increased energy consumption and costs

Compression chillers for comfort cooling

Common problem with open recooling circuits:

 

  • severe corrosion due to strong oxygen enrichment in the cooling water
  • severe corrosion due to chemical additives in the cooling water

product benefits

aquatherm blue pipe

  • high chemical resistance
  • no corrosion
  • absolute tightness over the entire life as fully welded system
  • no dissolution of sealing rings
  • high volume flows through dimensions up to DN 500
  • low system pressures (10 bar) make it possible to use fiber-reinforced polypropylene tubing
  • lower thermal expansion than conventional plastics (only 0.035 mm / mK)
  • more durable than steel and cheaper than stainless steel
  • environmentally friendly as recyclable
  • more favorable CO2 balance than steel or stainless steel in the production

Product benefits

aquatherm blue pipe TI 

 

  • low linear expansion
  • high chemical resistance
  • corrosion resistant
  • very good welding properties
  • no loosening of sealing rings or glue points
  • high impact strength
  • light weight
  • self-compensating
  • high self-insulation value
  • more durable than steel and cheaper than stainless steel
  • lower CO2 footprint in production than steel or stainless steel
  • Delivery pipe up to DN 300

PROCESSING

aquatherm pipes and fittings are connected by heat fusion. The plastic melts into a homogeneous, cohesive unit. Double material thickness at the joint – that means double security at the otherwise critical point of a piping system. With aquatherm fusion technology, you can quickly create a permanently sealed connection!

Depending on the dimension, pipes and fittings are joined by the heating element socket welding method, the butt welding method or the electric socket welding method.

Contact:  Aquatherm U.K. Ltd | 9 Saracen Close, Gillingham, Kent, England, ME8 0QN

Tel: 01444 250500 |  enquiries@aquatherm-uk.com